Multifamily Water Conservation Case Study | Confidential Client

16.49% Reduction in Water Consumption

A multifamily property in Washington, D.C. installed a 2-inch AF valve to reduce unnecessary water consumption and associated water and sewer costs.

Performance was measured over 122 days and four billing cycles, comparing post-installation consumption with corresponding prior-year periods using a same-season, matched-cycle methodology.

Results at a Glance

16.49%
Water Reduction

169,578 gallons
Water Saved in 122 Days

$15,123/year
Annualized Savings

5.95 months
Simple Payback

Measured Results

During the 122-day measurement period, the property reduced water consumption by 226.73 CCF, equivalent to 169,578 gallons.

The measured reduction resulted in approximately $5,057 in water and sewer cost savings during the four billing-cycle reporting period. Case Study - 16% savings

Based on measured performance, the results annualize to approximately:

  • 508,735 gallons of water saved

  • $15,123 in annual operating savings

  • $1,260 in monthly savings Case Study - 16% savings

Project Details

Property Type: Multifamily
Location: Washington, D.C.
Client: Confidential
Valve Size: 2-inch
Investment: $7,499
Measurement Period: 122 days / 4 billing cycles
Measurement Method: Same-season, matched-cycle comparison

Return on Investment

With an initial valve investment of $7,499, measured performance resulted in an estimated 5.95-month simple payback.

Based on the report's stated assumptions, projected cumulative ROI reaches 470.4% over three years and 824.4% over five years. Case Study - 16% savings

Water Efficiency. Measured Results.

16.49% less water. 169,578 gallons saved in 122 days.

Results are based on measured, same-season billing-cycle comparisons following installation. Individual results vary based on property characteristics, water usage, billing rates and operating conditions.